AL-2020/2035/2040/2050/2060 SIMULATION, TROUBLE CODES 10 - 21
46 19 Exposure mode setup [Function]
<
γ table setting>
When this simulation is executed, the code number of the current set gamma table is displayed.
(Default: 2)
Enter the code number corresponding to the desired gamma table, and press [Exposure mode
selector] key (or [ ] [ ] key for the AL-2050/2060) to change the mode and write into the
EEPROM.
<AE operation mode>
When setting the
γ table, press [Exposure mode selector] key (or [ ] key for the AL-2050/
2060) to change to the AE operation mode, and the current set code number of the AE opera-
tion mode is displayed. (Default: 0)
Enter the code number corresponding to the desired AE operation mode and press [Exposure
mode selector] key (or [ ] [ ] key for the AL-2050/2060) to change the mode and write into
the EEPROM.
<PHOTO image process setting>
When [Exposure mode selector] key (or [ ] key for the AL-2050/2060) is pressed in AE oper-
ation mode setting, the mode is changed to the PHOTO image process setting and the code
number of the current set PHOTO image process setting is displayed. (Default: 1)
Enter the code number corresponding to the desired PHOTO image process setting and press
[Exposure mode selector] key (or [ ] [ ] key for the AL-2050/2060) to change the mode
and write into the EEPROM.
[Operation]
The operation is similar to simulation 43-01.
20 SPF/RSPF exposure
correction
(excluding AL-2020)
[Function]
Used to adjust the exposure correction amount in the SPF/RSPF mode. The adjustment is
made by adjusting Vref voltage variation for the OC mode.
When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to save the setting and make a copy.
When the set value is increased, copy becomes darker. When the set value is decreased, copy
becomes lighter. (Adjustment range: 1 – 99)
[Operation]
The operation is similar to simulation 46-01.
Main
code
Sub
code
Contents Details of function/operation
Mode
Display item
(AL-2050/
2060)
Display lamp
(AL-2020/
2035/2040)
Code
number
Setting content Remark
γ GAMMA OFF
1 Image quality priority mode
2 Toner consumption priority mode Default
AE AE AE
0 Lead edge stop Default
1 Real time process
PHOTO PHOTO PHOTO
1 Error diffusion process Default
2 Dither process
Mode
Display item
(AL-2050/2060)
Display lamp
(AL-2035/2040)
Default Remark