AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 9
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark
S
W
35
1 Cover function default
setup
1: Yes 0: No
No 0
2 Inhibited to use 1
3 CI delete max. OFF time Bit No. 3 4
10sec
05sec 0 0
10sec 0 1
4 15sec 1 0
1
20sec 1 1
5 Answering machine call
number setting
Binary input
6 times
0
6 Bit No.
Set range
5678
0 to 15 times
1
7 1
8 0
S
W
36
1 CNG detection completion
time
Binary input
45sec
0 When a value outside
the set range is set,
the initial value is set.
2 Bit No.
Set range
12345678
1 to 255sec
0
3 1
4 0
5 1
6 1
7 0
8 1
S
W
37
1 Inhibited to use 0
2 1
3 0
4 1
5 0
6 1
7 0
8 1
S
W
38
1 Protocol monitor Bit No. 1 2
Not output
0Not output 0 0
Not output 0 1
2 Output 1 0
0
Output only in an error 1 1
3 Protocol monitor save 1: Yes 0: No Yes 1
4 Inhibited to use 0
5 Flash send time (U.K.,
Netherlands, Luxembourg,
Belgium, France: Inhibited
to use)
Bit No. 5 6
90ms
090ms 0 0
180ms 0 1
6 270ms 1 0
0
360ms 1 1
7 Transfer function 1: Allow 0: Inhibit Allow 1
8 Inhibited to use 0
S
W
39
1 Inhibited to use 0
2 0
3 1
4 DTMF signal send time Binary input
80ms
0 When a value outside
the set range is set,
the initial value is set.
5 Bit No.
Set range
45678
70 to 310ms
10ms unit
1
6 0
7 0
8 0
S
W
40
1 Number of times of recall
in error
Binary input
1 times
0 Refer to User program
“RECALL TIMES
(LINE ERROR)”.
When a value outside
the set range is set,
the initial value is set.
2 Bit No.
Set range
12345678
0 to 5 times
0
3 0
4 0
5 0
6 0
7 0
8 1