AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 12
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark
S
W
51
1 DTMF send level (High
group) setup
Binary input
–6dBm
0 When a value outside
the set range is set,
the initial value is set.
2 Bit No.
Set range
12345
0 (0.0dBm) to
21 (–21.0dBm)
1.0dBm unit
0
3 1
4 1
5 0
6 CED detection time 1: 500ms 0: 1000ms 1000ms 0
7 Busy tone detection cycle Bit No. 7 8
2puls
02puls 0 0
4puls 0 1
8 6puls 1 0
0
10puls 1 1
S
W
52
1 Busy tone detection level Bit No. 1 2
–43dB
0–43dB 0 0
–35dB 0 1
2 –33dB 1 0
0
–30dB 1 1
3 Inhibited to use 0
4 Super G3 disabled in the
last call-out of recall in
case of an error
1: Super G3 enabled 0: Super G3 disabled
Super G3 disabled 0
5 Error process in RTN
reception
1: Not error 0: Error
Error 0
6 Inhibited to use 0
7 0
8 V.34 control channel
communication speed
1: 2400bps 0: 1200bps
1200bps 0
S
W
53
1 Maximum DTMF send
level
Binary input
0dBm
0
2 Bit No.
Set range
1234
0 (0.0dBm) to
15 (–15.0dBm)
0
3 0
4 0
5 DTMF send level
(difference between high
and low level)
Binary input
+2.0dBm
1
6 Bit No.
Set range
5678
0 (–2.0dBm) to
15 (+5.5dBm)
0.5dBm unit
When set to 0: Low group
= High group – (–2.0) dBm
0
7
0
8
0
S
W
54
1 Scan effective image area
sub scan lead edge image
loss (RSPF)
Binary input
96 lines
0
2 Bit No.
Set range
1234
0 to 240 lines
16 lines interval
1
3 1
4 0
5 Scan effective image area
sub scan rear edge image
loss (RSPF)
Binary input
144 lines
1
6 Bit No.
Set range
5678
0 to 240 lines
16 lines interval
0
7 0
8 1
S
W
55
1 CI signal OFF detection
enable time
Binary input
1200ms
1
2 Bit No.
Set range
1234567
0 to 1270ms
10ms unit
1
3 1
4 1
5 0
6 0
7 0
8 Inhibited to use 0