EasyManua.ls Logo

Sharp AR-162

Sharp AR-162
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(3) Developing bias voltage adjustment
Note: Use a digital multi-meter with an internal resistance of
10M or more.
1) Set the digital multi-meter range to DC700V.
2) Put the test rod of the digital multi-meter on the developing bias
voltage output check pin.
3) Turn on the power.
4) Adjust the adjustment volume VR31 so that the output voltage is
within the specified range shown below.
<Adjustment specification>
Mode Specification
Developing bias voltage DC-400±8V VR31
(4) Grid bias voltage adjustment
Note: Use a digital multi-meter with an internal resistance of
10M or more.
1) Set the digital multi-meter range to DC700V.
2) Put the test rod of the digital multi-meter on the grid bias voltage
output check pin.
3) Turn on the power.
4) Adjust the adjustment volumes (VR51, VR52) so that the output
voltage is within the specified range. (The voltage is outputted in
the grid bias high output mode during warming up, and in the grid
bias low output mode after completion of warming up.)
<Adjustment specification>
Mode Specification
Grid bias LOW DC-400±20V VR52
Grid bias HIGH DC-525±10V VR51
B. Mechanism section
(1) Image lead edge position adjustment (SIM 50-1)
a. OC image lead edge position adjustment
Note: In advance to this adjustment, the sub scanning magnification
ratio adjustment must be performed.
1) Set a scale on the OC table as shown below.
2) Make a copy.
3) Check the copy output. If necessary, perform the following adjust-
ment procedures.
4) Execute SIM 50-1.
5) Set the OC lead edge position set value (Exposure display
<AUTO> ON) to 99.
The OC image scanning start position is shifted inside the docu-
ment edge.
6) Set the main cassette lead edge void adjustment value (Exposure
display <PHOTO> ON) * to 1.
The lead edge void becomes the minimum.
7) Set the print start position value (Exposure display <EXP1> ON)
to 99 and make a copy.
The print start position is shifted inside the document edge.
8) Measure the image loss R of the copied image. Enter the set
value of the image scanning lead edge position (Exposure display
<AUTO> ON) again.
1 step of the set value corresponds to about 0.127mm shift.
Calculate the set value from the formula below.
99 - R/0.127 (mm) = Image loss set value <R: Image loss meas-
urement value (mm)>
Example: 99 - 4/0.127 = 99 - 31.5 = about 67
Note: If the set value is not obtained from the above formula,
perform the fine adjustment.
5
10
5mm
4mm
*The dimension varies depending on the model.
10
5mm
0mm
5
* The scanning edge is set.
(A line may be printed by scanning the document edge.)
AR-162 [6] ADJUSTMENT 11/1/2000
AR-162 ADJUSTMENTS 2

Related product manuals