[10] MAINTENANCE
1. Maintenance table
✕: Check (Clean, adjust, or replace when required.) : Clean ▲: Replace : Adjust ✩: Lubricate
Unit name Part name
When calling or
replacing the kit
150k
Transfer section Charger unit
Transfer paper guide
Optical section Lamp unit Reflector
Mirror
No. 2/3 mirror unit Mirror
Pulley
✕✕
CCD peripheral Lens
Glass Table glass
White plate
Other Drive wire
✕✕
Rail
✕✩ ✕✩
Document cover
Document size sensor
LSU Dust-proof glass
Paper feed section Multi paper feed section Takeup roller
Paper feed roller
Spring clutch
✩✩
Cassette section Paper feed roller
Spring clutch
✩✩
Paper transport section PS roller
Transport (paper exit) rollers
Spring clutch
✩✩
Fusing section Upper heat roller
▲
Pressure roller
Pressure roller bearing
✕✩
Upper separation pawl
✕
Lower separation pawl
✕
Drive section Gears
✕✩ ✕✩
Belts
✕
Paper exit section Ozone filter
✕✕
∗1: Recommendable replacement time: 30K (A4 (8.5" × 11"), 6% print)
2. Maintenance display system
Toner Life 13K
Remaining
quantity check ∗1
a. Press and hold the density adjustment LIGHT key for more than 5 sec, and the machine will enter the
user program mode.
b. Press and hold the "%" key for more than 5 sec, and the remaining quantity will be displayed on the copy
quantity display in one of the following levels: (Remaining quantity display levels: 100%, 75%, 50%, 25%,
10%, LO)
c. Press the density adjustment LIGHT key to cancel.
Remaining
quantity
NEAR EMPTY
About 10%
EMPTY
LED ON Flash
Machine Operation allowed Stop
Developer Life 30K
LED ON at 30K of the developer count.
Machine Selection is available between Not Stop and Stop by Service Simulation (SIM 26-37) Setup.
(If Stop is selected, the LED will flash and stop at 30K.)
∗ Default: Not Stop
∗ Clear: SIM 42-1
Maintenance LED Selection is available among 30K, 15K, 10K, 7.5K, 5K, and free (no lighting) with SIM 21-1.
∗ Default: 30K
∗ Clear: SIM 20-1
Machine Not stop.
∗1: Installation of a new toner cartridge allows to display the remaining quantity.
∗1
AR-162 [10] MAINTENANCE 11/21/2000