AR-M236/M276/M237/M277 SIMULATION 8 - 11
Reset is not performed when the machine enters the aging
mode.
Operation/procedure
1. Enter the interval aging cycle time (sec) with the 10-key pad.
Refer to SIM 7-1.
2. Press the [START] key.
When the [START] key is pressed in aging, copying is performed con-
tinuously. This simulation is used to set the time interval between copy
operations in the unit of second.
This setting is valid when SIM 7-1 (Intermittent setting) is enabled.
Operation/procedure
1. Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2. The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3. After completion of warming up, "WARM UP COMPLETED" is dis-
played and the control returns to the initial screen.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
(
∗) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [START] key.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: –25V increment
(
∗) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
7-6
Purpose Setting/Operation test/check
Function (Purpose) Used to set the cycle of intermittent aging.
Item Operation
Setting range 1-255
Default 3
7-8
Purpose Setting/Operation test/check
Function
(Purpose)
Used to set the display of the warm-up time.
Item Operation
8
8-1
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item Content
Installation
range
Default
1AE AE (
∗) 200-550 400 (–400V)
2 TEXT Character 450 (–450V)
3 TEXT/PHOTO Character/Photo 450 (–450V)
4 PHOTO Photo 450 (–450V)
5 SUPER/PHOTO Super photo 400 (–400V)
6 TONER SAVE Toner save 376 (–376V)
8-2
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each copy mode
and the control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Item Content
Setting
range
Default
1AE AE (
∗)1-83 (–530V)
2 TEXT Character 5 (–580V)
3 TEXT/PHOTO Character/Photo 5 (–580V)
4 PHOTO Photo 5 (–580V)
5 SUPER/PHOTO Super photo 3 (–530V)
6 TONER SAVE Toner save 2 (–505V)
NO. Set value Grid High Grid Low
1 480 –480V –350V
2 505 –505V –375V
3 530 –530V –400V