AR-M236/M276/M237/M277 SIMULATION 8 - 12
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to 480V (pattern 1), the
grid low voltage is 350V.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is highlighted.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: -25V increment
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to 480V (pattern 1), the
grid low voltage is 350V.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
The minimum increment is 2V.
The result of (Set value 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [START] key.
4 555 555V 425V
5 580 580V 450V
6 605 605V 475V
7 630 630V 500V
8 655 655V 525V
8-3
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Item Content
Setting
range
Default
1AE AE (
)1-83 (400V)
2 TEXT Character 5 (450V)
3 TEXT/PHOTO Character/Photo 5 (450V)
4 PHOTO Photo 5 (450V)
5 SUPER/PHOTO Super photo 3 (400V)
6 TONER SAVE Toner save 2 (375V)
NO. Set value Grid High Grid Low
1 480 480V 350V
2 505 505V 375V
3 530 530V 400V
4 555 555V 425V
5 580 580V 450V
6 605 605V 475V
7 630 630V 500V
8 655 655V 525V
NO. Set value Grid High Grid Low
8-10
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each printer mode and the
control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item Content
Installation
range
Default
1 DENS1(600) Density 1 (600dpi) 200-550 400 (400V)
2 DENS2(600) Density 2 (600dpi) 450 (450V)
3 DENS3(600) Density 3 (600dpi) 450 (450V)
4 DENS4(600) Density 4 (600dpi) 450 (450V)
5 DENS5(600) Density 5 (600dpi) 500 (500V)
6 TS(600) Toner save (600dpi) 350 (350V)
7 DENS1(1200) Density 1 (1200dpi) 300 (300V)
8 DENS2(1200) Density 2 (1200dpi) 350 (350V)
9 DENS3(1200) Density 3 (1200dpi) 376 (376V)
10 DENS4(1200) Density 4 (1200dpi) 426 (426V)
11 DENS5(1200) Density 5 (1200dpi) 500 (500V)