AR-M236/M276/M237/M277 SIMULATION 8 - 12
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to ā480V (pattern 1), the
grid low voltage is ā350V.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is highlighted.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: -25V increment
(
ā) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to ā480V (pattern 1), the
grid low voltage is ā350V.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
The minimum increment is 2V.
The result of (Set value ā 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [START] key.
4 555 ā555V ā425V
5 580 ā580V ā450V
6 605 ā605V ā475V
7 630 ā630V ā500V
8 655 ā655V ā525V
8-3
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Item Content
Setting
range
Default
1AE AE (
ā)1-83 (ā400V)
2 TEXT Character 5 (ā450V)
3 TEXT/PHOTO Character/Photo 5 (ā450V)
4 PHOTO Photo 5 (ā450V)
5 SUPER/PHOTO Super photo 3 (ā400V)
6 TONER SAVE Toner save 2 (ā375V)
NO. Set value Grid High Grid Low
1 480 ā480V ā350V
2 505 ā505V ā375V
3 530 ā530V ā400V
4 555 ā555V ā425V
5 580 ā580V ā450V
6 605 ā605V ā475V
7 630 ā630V ā500V
8 655 ā655V ā525V
NO. Set value Grid High Grid Low
8-10
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each printer mode and the
control circuit.
Section Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item Content
Installation
range
Default
1 DENS1(600) Density 1 (600dpi) 200-550 400 (ā400V)
2 DENS2(600) Density 2 (600dpi) 450 (ā450V)
3 DENS3(600) Density 3 (600dpi) 450 (ā450V)
4 DENS4(600) Density 4 (600dpi) 450 (ā450V)
5 DENS5(600) Density 5 (600dpi) 500 (ā500V)
6 TS(600) Toner save (600dpi) 350 (ā350V)
7 DENS1(1200) Density 1 (1200dpi) 300 (ā300V)
8 DENS2(1200) Density 2 (1200dpi) 350 (ā350V)
9 DENS3(1200) Density 3 (1200dpi) 376 (ā376V)
10 DENS4(1200) Density 4 (1200dpi) 426 (ā426V)