AR-M236/M276/M237/M277 SIMULATION 8 - 49
Note: Executable only when the FAX is installed.
Operation/procedure
Select "1: YES" with the 10-key and press the [START] key. The FAST
storage data are cleared. (When "2: NO" is selected, the simulation is
canceled.)
Note: Executable only when the FAX is installed.
Operation/procedure
When the relay state of the polarity reverse relay, the handset hook
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup (real time). The
display of change is kept until an interruption command is supplied by
pressing the [CUSTOM SETTINGS] key.
Note: Executable only when the FAX is installed.
Operation/Procedure
1. Enter the set value. (Valid only 0 to 8)
2. The entered bit is alternatively switched between "0" and 1" and
the target signal name is highlighted.
3. Press the [START] key to send the signal.
When the [CUSTUM SETTINGS] key is pressed, the output is termi-
nated.
Note: Executable only when the FAX is installed.
Operation/procedure
The fixed data received from the line are checked and the result is dis-
played.
When data are coincident, "OK" is displayed. When not, "NG" is dis-
played.
Note: Executable only when the FAX is installed.
Operation/Procedure
Signal detection is checked and the result is displayed.
Note: Executable only when the FAX is installed.
Operation/procedure
The send/receive test is performed, and the time required for send/
receive of the image data in the test is measured and displayed.
66-24
Purpose Data clear
Function
(Purpose)
Used to clear the FAST storage data. (SEC only)
Section FAX
Item Data Initializing
66-30
Purpose Operation test/check
Function (Purpose) Used to set the TEL/LIU.
Section FAX
Item Operation
Item
Notification contents
Signal low Signal high
HS2 ON OFF
HS1 ON OFF
RHS ON OFF
EXHS ON OFF
66-31
Purpose Setting
Function (Purpose) Used to set the TEL/LIU.
Section FAX
Item Operation
66-32
Purpose Operation test/check
Function (Purpose) Receive data check
Section FAX
Item Operation
66-33
Purpose Operation test/check
Function (Purpose) Signal detection check
Section FAX
Item Operation
66-34
Purpose Operation test/check
Function (Purpose) Communication time measurement display
Section FAX
Item Operation
Setup on the user
side when executing
communication
Communication
means
Picture quality
Density
ECM
Sender information
: Memory send
: Normal Character
: Lighter
:ON
:OFF
Measuring
range
Send From flag reception before sending of
image data until sending of RCP frame
Receive From flag reception before reception of
image data until reception of RCP frame