ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
The built-in protective de-
vice may prevent the unit
from operating when used
out of this range.
Condensation may form
on the air outlet if the unit
operates continuously in
the COOL or DRY mode
when humidity is over 80
percent.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to ve minutes after the unit is turned on
to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an auto-
matic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the in-
side and outside fans stop operating.
After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
HEATING EFFICIENCY
The unit employs a heat pump that draws heat from the outside air and releases it into the room.
The outside air temperature therefore greatly affects the heating ef ciency.
If the heating ef ciency is reduced due to low outside temperatures, use an additional heater.
It takes time to warm up and heat the entire room because of the forced air circulation system.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re-start in the same settings which were active be-
fore the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be re-set after power recovery.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower
in the HEAT mode will save approximately 10 percent in power consumption.
Setting the temperature lower than necessary during cooling operation will result in increased
power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
Blocking direct sunlight during cooling operation will reduce power consumption.
Close the windows and doors during cooling and heating operations.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
The indoor unit still consumes a small amount of power when it is not operating.
INDOOR TEMP. OUTDOOR TEMP.
COOLING
upper limit
32˚C 46˚C
lower limit
21˚C -10˚C
HEATING
upper limit
27˚C 24˚C
lower limit
- –15˚C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp AY-XP12GHR and is the answer not in the manual?

Sharp AY-XP12GHR Specifications

General IconGeneral
BrandSharp
ModelAY-XP12GHR
CategoryAir Conditioner
LanguageEnglish

Related product manuals