EasyManua.ls Logo

Sharp LC-42SB45U - Initial Set-Up; Ypbpr Mode Display Adjustment

Sharp LC-42SB45U
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2008-03-14
LC-42SB45U
23
2>. Luminance > 400 cd/m
2
in the center of the screen when Brightness control at 100; Contrast control at 100 for CMO 26”, 32”, 42” panels.
2) YPbPr Mode display adjustment
White balance adjustment
General set-up :
Equipment Requirement: Minolta CA-110 or Equivalent Color analyzer
Quantum Data Pattern Generator 802G , 802BT or equivalent instrument
Input requirements:
Input Signal Type : YPbPr signal
1. 720P mode, TVBar100 pattern by 802G or 802BT.
2. Select Smart picture to Personal mode and check the x, y data.
Input Signal Strength : 1 Vpp for Y signal ; 700 mVpp for Pb & Pr signal
Input Injection Point : AV1 YPbPr (RAC jack)
720P, TVBar100 pattern
Alignment method:
Initial Set-up:
1. Select source as “AV1”.
2. Set Smart picture as “Personal” and to be Contrast =50,
Brightness=50 , at normal menu mode.
3. Apply “TVBar100” pattern (with black & white bar )by signal generator.
4. Enter factory mode menu: press Numeric keys “062596” then perss Display key (FAC mode menu). Then select “Factory”
item.
Alignment:
1. At FAC mode menu, select AUTO_COLOR item. Then press “OK” key to adjust ADC_GAIN_R, ADC_GAIN_G,
ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then store those values to NVM.
2. Apply Flat_73 pattern or 75IRE pattern.
3. Set color temperature to “NORMAL”.
3. Copy CLR_TEMP_R, CLR_TEMP_G and CLR_TEMP_B values from “NORMAL” color temperature in Analog TV mode.
Check whether (x,y) color coordinates meet “NORMAL” color specification below. If color coordinates are out of
specification, fine-tune CLR_TEMP_R, CLR_TEMP_G and CLR_TEMP_B values. Then store those values to NVM. ( R/G/B
gain value <= 130 )
4. Set color temperature to “WARM”.
5. Copy CLR_TEMP_R, CLR_TEMP_G and CLR_TEMP_B values from “WARM” color temperature in Analog TV mode.
Check whether (x,y) color coordinates meet “WARM” color specification below. If color coordinates are out of specification,
fine-tune CLR_TEMP_R, CLR_TEMP_G and CLR_TEMP_B values. Then store those values to NVM. ( R/G/B gain value
<= 130 )
6. Set color temperature to “COOL”.
7. Copy CLR_TEMP_R, CLR_TEMP_G and CLR_TEMP_B values from “COOL” color temperature in Analog TV mode. Check
whether (x,y) color coordinates meet “COOL” color specification below. If color coordinates are out of specification, fine-tune
CLR_TEMP_R, CLR_TEMP_G and CLR_TEMP_B values. Then store those values to NVM. ( R/G/B gain value <= 130 )
Color temperature Normal/Warm/Cool (x, y) co-ordinates specification:
Picture Mode x y
Normal (9000oK) 0.289±0.010 0.291±0.010

Table of Contents

Other manuals for Sharp LC-42SB45U

Related product manuals