LC-65D90U
17
» Precautions in handling the liquid crystal panel
1. Handle it in a clean room. (above 50% humidity)
2. The worker must wear an earth band.
3. Be careful not to drop, vibrate and shock the panel.
4. Use an ionizer. (within 30 cm)
44. Remove the 20 lock screws from the LCD panel and detach the LCD panel.
45. Remove the 24 lock screws from the sheet angle, and detach the sheet angles.
46. Remove the reflection/deflection, prism, diffusion sheets and diffusion panel.
47. Remove the 12 lock screws from the lamp holder and detach the lamp holders -A , -B from the lamp unit.
45
47
46
47
48
44
45
Diffusion Panel
(PCOVUA069WJZZ)
Diffusion Sheet
(PSHEPA377WJZZ)
Prism Sheet
(PSHEPA376WJZZ)
Reflection/deflection Sheet
(PSHEPA375WJZZ)
Lamp Holder-A, x2
(LHLDZA601WJKZ)
Lamp Unit, x16
(KLMP-A079WJZZ)
Lamp Holder-B, x2
(LHLDZA602WJKZ)
Reflection Mirror
(PMiR-A085WJZZ)