18
LC-65D90U
ADJUSTMENT PROCEDURE
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should
become improper or an adjustment is required due to part replacement, make an adjustment according to the
following procedure.
1. After replacement of any PWB unit and/or IC for repair, please note the following.
When replacing the following units, make sure to prepare the new units loaded with updated software.
DIGITAL unit: DKEYDD392VJ13
2.Upgrading of each microprocessor software
Caution: Never "POWER OFF" the unit when software upgrade is ongoing.
Otherwise the system may be damaged beyond recovery.
2-1 Software version upgrade
The model employs the following software.
» Main software
» Monitor microprocessor software
The main software and the monitor microprocessor software can be upgraded by using a general-purpose SD
memory card.
The followings are the procedures for upgrading, explained separately for each of the main software, the
monitor microprocessor software.
2-2 Main software version upgrade
Get ready before you start.
» SD memory card of 32MB or higher capacity
» PC running on Windows 98/98SE/ME/2000/XP operating system
» SD memory card reader/writer with USB connectivity.
» SD memory card formatting software
(Downloadable at http://panasonic.jp/pavc/cs/sd/download/sd_formatter.html)

Related product manuals