MX-C250 SIMULATION 6 – 25
43-4
Purpose
Setting
Function (Purpose)
Used to set the fusing Target temperature
of each operation mode (continuation of
SIM 43-01)
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
<Code descriptions>
Group C Europe U.K. AUS AB_A
Group Destination
Item Display Content
Setting
range
Default value
Acc. Desti-
nation set-
ting(O/X)
Group
A
Group
B
Group
C
1
PLAIN
SwA
HL_UM PLAIN BW DUP Black-White plain paper duplex TH_UM set value
70 - 230 160 170 170
O
2 PLAIN BW DUP APP CNT
Black-White plain paper duplex fusing temperature
application start image screen number
0 - 60 0 0 0
O
3 HL_UM PLAIN CL DUP Color plain paper duplex TH_UM set value
70 - 230 165 175 175
O
4 PLAIN CL DUP APP CNT
Color plain paper duplex fusing temperature appli-
cation start image screen number
0 - 60 0 0 0
O
1
PLAIN
SwB
HL_UM PLAIN BW DUP Black-White plain paper duplex TH_UM set value
70 - 230 170 175 175
O
2 PLAIN BW DUP APP CNT
Black-White plain paper duplex fusing temperature
application start image screen number
0 - 60 0 0 0
O
3 HL_UM PLAIN CL DUP Color plain paper duplex TH_UM set value
70 - 230 175 180 180
O
4 PLAIN CL DUP APP CNT
Color plain paper duplex fusing temperature appli-
cation start image screen number
0 - 60 0 0 0
O
1
Other
HL_UM PLAIN BW DUP Black-White plain paper duplex TH_UM set value
70 - 230 170 170 170
X
2 HEAVY BW DUP APP CNT
Black-White plain paper duplex fusing temperature
application start image screen number
0 - 60 1 1 1
X
3 HL_UM PLAIN CL DUP Color plain paper duplex TH_UM set value
70 - 230 170 170 170
X
4 HEAVY CL DUP APP CNT
Color plain paper duplex fusing temperature appli-
cation start image screen number
0 - 60 1 1 1
X
TH_UM Fusing upper thermister (main) HL_UM Heater lamp upper
TH_LM Fusing lower thermister (main) HL_LM Heater lamp lower
TH_E Fusing thermister (external heat roller) HL_E Heater lamp (external heat roller)
Group Destination
Group A Japan China AB_B -
Group B U.S.A. Canada Inch -
Group C Europe U.K. AUS AB_A