Diagnostics and troubleshooting
140
Error code
Description
Action
242.33
Paper fed from tray 3 never arrived at the sensor
(tray 2 pass-through).
See
“Sensor (tray 2 pass-through): Paper
failed to arrive service check” on page
147
.
242.34
Paper fed from tray 3 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
earlier than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too early
service check” on page 151
.
242.35
Paper fed from tray 3 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
later than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too late
service check” on page 153
.
242.37
Paper fed from tray 3 never cleared the sensor
(tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass
through): Paper failed to clear service
check” on page 158
.
242.38
Paper fed from tray 3 was detected later than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass-through): Paper arrived too late
service check” on page 160
.
242.41
Paper fed from tray 4 remains detected at the
sensor (tray 2 pass
through) or at the sensor (tray
2 trailing edge) after the printer is turned on.
See
“Sensors (tray [x] trailing edge and
pass-through) static jam service check” on
page 144
.
242.42
Paper fed from tray 4 was detected earlier than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass
through): Paper arrived too early
service check” on page 145
.
242.43
Paper fed from tray 4 never arrived at the sensor
(tray 2 pass-through).
See
“Sensor (tray 2 pass-through): Paper
failed to arrive service check” on page
147
.
242.44
Paper fed from tray 4 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
earlier than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too early
service check” on page 151
.
242.45
Paper fed from tray 4 cleared the sensor (tray 2
pass-through) or the sensor (tray 2 trailing edge)
later than expected.
See
“Sensors (tray [x] trailing edge and
pass-through): Paper cleared too late
service check” on page 153
.
242.47
Paper fed from tray 4 never cleared the sensor
(tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass
through): Paper failed to clear service
check” on page 158
.
242.48
Paper fed from tray 4 was detected later than
expected at the sensor (tray 2 pass-through) or at
the sensor (tray 2 trailing edge).
See
“Sensors (tray [x] trailing edge and
pass-through): Paper arrived too late
service check” on page 160
.
242.84
Failed to pick last sheet of paper.
See
“Tray actuator and spring service
check” on page 137
.
242.91
Paper remains detected at the sensor (tray 2
pass
through) or at the sensor (tray 2 trailing edge)
after the printer is turned on. Paper source is
undetermined.
See
“Sensors (tray [x] trailing edge and
pass-through) static jam service check” on
page 144
.
242.92
Paper was detected earlier than expected at the
sensor (tray 2 pass-through) or at the sensor (tray
2 trailing edge). Paper source is undetermined.
See
“Sensors (tray [x] trailing edge and
pass
through): Paper arrived too early
service check” on page 145
.