SHARP Document Solution Centre
15
Consumable Quick Reference Guide:-
Total Maintenance 500K 1000K 1500K 2000K 2500K
Process
Drum MX-850GR x
x
x
Developer MX-900GV x
x
x
Developer Maintenance Kit MX-900DK
Heat Roller Kit MX-950HK
x
x
x
Web Cleaning Kit MX-950WC
Transfer Transfer Belt Kit MX-900TT x
x
x
Maintenance Indications:
TA Maintenance [All] Counter has reached specified limit
DK
Black Drum (Counter) has reached
the specified life.
Replace OPC Drum
Process
Section
(Drum)
VK
Black Developer (Counter) has reached
the specified life.
Replace Developer.
Process
Section
(Developer)
FK3
Fuser Web Cleaning Counter has reached
the specified limit.
Replace the Fuser Web
Cleaning Kit.
Fuser Section
Starting Powder:
The following starting powder should be applied to the relevant consumable item during maintenance:-
Starting Powder OPC Drum Primary Transfer Belt
MX-M904
MX-M1054
MX-M1204
UKOG-0312FCZZ
[Stearic Acid]
UKOG-0312FCZZ
[Stearic Acid]