25
E
Others
Function
Command Direction
Parameter Reply Control/Response contents *
SCREEN SIZE
(DVI-D, D-SUB)
WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
No
SCREEN SIZE
(HDMI, COMPONENT, VIDEO)
WIDE WR 1-5 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
VOLUME VOLM WR 0-31 0-31
MUTE MUTE WR 0-1 0-1 0: OFF, 1: ON
INFORMATION MODEL INF1 R Value
Yes
SERIAL NO SRNO R Value
BRIGHT VLMP WR 0-31 0-31 No
TEMPERATURE SENSOR DSTA R 0 Internal temperature normal
Yes
1 Internal temperature abnormal (Standby mode)
2 Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operation.)
3 Internal temperature abnormal (Brightness of the backlight decreases.)
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION ERRT R Value Temperature at temperature sensors are returned in the following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
This monitor does not have sensors 2 and 3. All return the same value as
sensor 1.
Indicates a temperature sensor abnormality when “126” is returned.
No
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
Yes
R 0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Waiting mode by No Signal
6 Standby mode by abnormal temperature