No.
ERROR print Details of ERROR
12 RCVRDY : ERROR RCVRDY is not set.
(Not possible to receive. TRQ-
occurs during the
implementation of check ii.)
13 RCVRDY INT : ERROR RCVRDY interrupt does not
occur.
14 SD-RD : ERROR SD-RD LOOP ERROR
(DATA ERROR)
15 SD-RD : ERROR SD-RD LOOP ERROR
(DATA ERROR, FRAMING
ERROR, and others)
16
17
18 CI : ERROR The logic of C1 is ON, but
different from those in 1~3.
19 CD : ERROR The logic of CD is ON, but
different from those in 1~3.
How to exit the program.
Press the CANCEL key to exit the program.
5) LCD/POPUP/POLE DISPLAY & PRINTER
DIAGNOSTICS
The program tests the LCD, popup and pole displays of the UP-600.
The following menu appears on the screen. The cursor shown in
reverse video can be moved using the up/down arrow keys. Move the
cursor to the menu item you want to execute and select by pressing
the Enter key to execute the corresponding Diag. program. You can
return the screen to this submenu by pressing the CANCEL key.
The test program displays the following test patterns in the order
shown. You can move to the next pattern by pressing the ENTER
key.
You can return the screen to this submenu by pressing the ENTER
key when the final test pattern is shown on the screen or by pressing
the CANCEL key during the implementation of the check.
5)-1. Liquid Crystal Display Check
Checking
The screen shows the following test patterns. Press the ENTER
key to move to the next test pattern.
i. Black and white checkered pattern with 1-dot spacing.
ii. Reverse-videoed test pattern of i
iii. Vertical stripe pattern with 1-dot spacing
iv. Reverse-videoed test pattern of iii
v. Horizontal stripe pattern with 1-dot spacing
vi. Reserve-videoed test pattern of v
vii. The outermost periphery of LCD’s active area is displayed in
1-dot line.
viii. "H" pattern. "H" is displayed in 20 digits and 8 lines.
"H" is displayed in 19 digits only in the 8th line.
PES&NES SENSOR Check
PRINTER CG Check
PRINTER Check
POLE Check
POPUP Check
LCD Check
DISPLAY&PRINTER DIAG
Dot pulse adjustment
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHH