5. Removing the optical mechanism unit
5-1. Pull out the ZOOM lever.
5-2. Remove 2 mechanism unit fixing screws.
5-3. Disconnect the relay connector for the thermal fuse.
5-4. Lift off the mechanism unit.
6. Removing the inlet PWB unit and the terminal panel
6-1. Remove the inlet PWB unit fixing screw.
6-2. Lift off the terminal panel and the PWB unit at the same time.
6-3. Remove 2 fixing screws for AC inlet (terminal panel side) to detach the unit and the panel.
5-2
5-4
5-3
5-1
ZOOM lever
Optical mechanism unit
Thermal fuse
Fan
6-3
6-2
6-3
6-1
Inlet PWB unit
Terminal panel