7. Conduction test 9. Note for battery replacement
l
Check conduction be-
tween the key fixing
plate and the fixing
angle.
Max. 25 R
Key fixing
plate
3
-
Key sheet
holding
Fixing angle
I
8. Current check
<Operation
current
checks
vcc
=
6.OV
I I
I
I
(System battery section)
1.
Press the OFF key.
2. Measure the current value. (After
1
sec.)
When
OFF:
30l.tA
or less
3. Press the ON key.
4. Measure the current value.
When ON: 1.7mA or less
Replacing
the
batteries
Batteries used in the Organizer:
Type
Lithum
battery
Lithum
battery
Model
Qty.
CR2032 2
CR2032 1
Use
Unit operation
Memory backup
The standard built-in clock and world city clock are powered by the
operating batteries.
Precautions
when
replacing
the
batteries
.
Before replacing the battery, be sure to press
Ic)FFJ
to
turn
the
power off.
Do not replace the memory backup battery while the operating
batteries are not in the Organizer or when they are depleted.
When the operating batteries become weak and you turn the
power on,
m
will be displayed and the following display
J
If the batteries become weaker, the power may go off during
operation. The memory contents will still be retained by the
memory backup battery. Replace the operating batteries to avoid
loss or alteration of data.
Do not remove both the operating and memory backup batteries at
the same time. All the data stored in the memory will be lost.
Before removing the batteries for replacement, jot down the impor-
tant data stored in the Organizer in hard copy form.
Precautions
on
battery
use
Always replace both operating batteries at the same time.
Do not use an old battery and a new one together.
Use only the specified lithium batteries.
Replace the memory backup battery at least every
5
years, or when
the message appears.
Battery
precautions
l
Keep the batteries out of the reach of children.
* When batteries become weak remove them from the Organizer
immediately. If depleted batteries are lefl in the Organizer for any
length of time, they might leak and cause corrosion inside the
Organizer.
l
Do not dispose of batteries by fire as they may explode.
Operating
batteries
Replacement
intervals
for
the
power
source
batteries
When
m
is displayed on the right side of the display, and the
LCD becomes too dim to read despite contrast adjustment, the
operating batteries are depleted. Press
m
to turn the power off
and then turn the power back on. If the following display appears
when the power is turned on, replace both operating batteries imme-
diately.
I
<RTTENTIOt-J>
Note: If you have an optional printer/cassette interface and a cas-
sette recorder,
copy
all the stored data in the Organizer before
replacing the batteries.