EasyManua.ls Logo

Shelly Wave i4 DC - Parameter No. 2 - SW2 Switch Type; Parameter No. 3 - SW3 Switch Type; Parameter No. 4 - SW4 Switch Type

Shelly Wave i4 DC
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter No. 2 - SW2 Switch type
This parameter defines how the Device should treat the switch (which type) connected to the
SW2 terminal.
Value size: 1 Byte
Default value: 2
Values & descriptions:
0 - momentary switch (push button),
1 - toggle switch (contact closed - ON / contact opened - OFF),
2 - toggle switch (device changes status when switch changes status)
Parameter No. 3 - SW3 Switch type
This parameter defines how the Device should treat the switch (which type) connected to the
SW3 terminal.
Value size: 1 Byte
Default value: 2
Values & descriptions:
0 - momentary switch (push button),
1 - toggle switch (contact closed - ON / contact opened - OFF),
2 - toggle switch (device changes status when switch changes status)
Parameter No. 4 - SW4 Switch type
This parameter defines how the Device should treat the switch (which type) connected to the
SW4 terminal.
Value size: 1 Byte
Default value: 2
Values & descriptions:
0 - momentary switch (push button),
1 - toggle switch (contact closed - ON / contact opened - OFF),
2 - toggle switch (device changes status when switch changes status)