PARTS LIST / SCHEMATICS / DIAGRAMS
Shelti Eye
2
Manual 28
SYMPTOMS WHEN
DART LANDS
INSIDE
TARGET SEGMENT.
4TARGET
“DEAD”
DURING
GAME &
TEST
MODE.
44BULL’S EYE
NOT SCORING
CORRECT
AMOUNT OF
POINTS.
4QUADRANT
OR
QUADRANTS
NOT SCORING
OR
MIS-SCORING.
1 SEGMENT
OR
SEVERAL
UNRELATED
SEGMENTS NOT
SCORING.
4Target
unplugged
at
Controller
Board.
Target
unplugged
at
Matrix
Switch.
Check Bull’s Eye
setting.
(BE = single)
(dBE = double)
If Bull’s Eye
deducts an
unexpected value
(other than 25 or
50 points), check
Matrix Switch.
Check Controller
Board
harness.
Check Matrix
Switch
&
connections.
Check Controller
Board.
Bad physical contact
between segment
&
Matrix Switch.
Check for
short on
Controller
Board.
Bad switch pad.
QUICK FIX:
Replace Target
Assembly.
See also
TARGET DETAILED SEGMENT
&/OR
QUADRANT ANALYSIS.
Check
Controller
Board.

Table of Contents