1.3 Technical Specifications
1.3.1 Specifications
Table 1-1Specifications
Model Ver.
Pipe
Heater
(kW)
Blower Power
(kW, 50/60 Hz)
Temperature
Range ()
Number
Of Trays
Total Tray
Capacity
(kg)
Outer
Dimensions
H×W×D (mm)
Inner
Dimensions
H1×W1×D1
(mm)
Weight
(kg)
CD-5(60Hz) A
200 1200×800×610
150
CD-5-HT(60Hz)
A
4 0.55
250
5 50
1380×860×731
660×600×550
200
CD-9(60Hz) A
200 1440×800×610
180
CD-9-HT
(50Hz/60Hz)
A
4.5 0.55
250
9 90
1640×920×731
900×600×550
252
CD-20 B
200 1700×1210×860
415
CD-20-HT B
9 1.5
250
20 200
1887×1310×1032
1000×990×800
587
CD-20L B
200 1865×1800×1060
550
CD-20L-HT B
18 1.5
250
20 350
2052×1900×1232
1200×1600×1000
778
Note: 1) Power supply: 3Φ, 230 / 400 / 460 / 575VAC, 50 / 60Hz. We reserve the right to change
2) "HT" stands for heat insulation model, the surface temperature specifications without prior notice.
of which will not be more than 80 when setup temperature is 250 .
3) When drying temperature is below 150 , "HT" models can
keep internal temperature accuracy of ±5 , when it is above
150 , internal temperature accuracy is ±12 .℃℃

Table of Contents