10(44)
1.3 Technical Specifications
1.3.1 Specifications
Table 1-1:Specifications
Model Ver.
Pipe
Heater
(kW)
Blower Power
(kW, 50/60 Hz)
Temperature
Range ()℃
Number
Of Trays
Total Tray
Capacity
(kg)
Outer
Dimensions
H×W×D (mm)
Inner
Dimensions
H1×W1×D1
(mm)
(kg)
CD-5(60Hz) A
200 1200×800×610
150
CD-5-HT(60Hz)
A
4 0.55
250
5 50
1380×860×731
660×600×550
200
CD-9(60Hz) A
200 1440×800×610
180
CD-9-HT
(50Hz/60Hz)
A
4.5 0.55
250
9 90
1640×920×731
900×600×550
252
CD-20 B
200 1700×1210×860
415
CD-20-HT B
9 1.5
250
20 200
1887×1310×1032
1000×990×800
587
CD-20L B
200 1865×1800×1060
550
CD-20L-HT B
18 1.5
250
20 350
2052×1900×1232
1200×1600×1000
778
Note: 1) Power supply: 3Φ, 230 / 400 / 460 / 575VAC, 50 / 60Hz. We reserve the right to change
2) "HT" stands for heat insulation model, the surface temperature specifications without prior notice.
of which will not be more than 80 when℃ setup temperature is 250 .℃
3) When drying temperature is below 150 , "HT" models can ℃
keep internal temperature accuracy of ±5 , when it is above ℃
150 , internal temperature accuracy is ±12 .℃℃