From the Hardware
Access Point Transceiver
Press and hold the recessed reset button for 10 seconds. The network audio status LED will briefly turn off to indicate the
unit is rebooting.
CAUTION: A factory reset deletes all Group associations and microphone Links saved in the device.
Audio Network Interface
Press and hold the reset button for 10 seconds. The front panel LEDs will flash to indicate the unit is rebooting.
Networked Charging Station
Turn off the power switch.
Press and hold the Link button.
While holding the Link button, turn on the power switch.
Continue to hold the Link button for 12 seconds until the LED illuminates amber.
From the Control Software
Open the Utility Tab of the MXW control software.
Select the Edit Properties button for the device.
Select the factory reset check-box.
Select Add Updates to save the setting to the edits queue.
Repeat for any additional devices.