Shure Incorporated
11/15
1.
2.
3.
4.
5.
6.
7.
All receivers in the same band should be set to the same group. You can set them manually, or use the Guided Frequency Set
up to walk you through the process.
Connect all the receivers in your system using Ethernet cables. For best results, use a network switch when connecting 3 or
more receiver units.
Important! To avoid interference, before you begin:
Turn off all transmitters for the systems you are setting up. This prevents them from interfering with the frequency scan.
Turn on the following devices so they are operating as they would be during the presentation or performance. This will allow
the scan to detect and avoid any interference from these devices:
Configured wireless systems or devices
Computers
Large LED panels
Effects processors
CD players
Using the Guided Frequency Setup
Set up a new system:
Push the control knob on the receiver and select 1.FrequencySetup > 1.1GuidedFrequencySetup.
Select Initialize My System and push the control knob to continue.
Turn off all transmitters you plan to use with your system.
Select start scan.
After the scan is done, push the control knob to assign frequencies to the receiver.
Turn on the transmitter you plan to use with this receiver.
Align the infrared (IR) ports on the transmitter and receiver, and push the sync button.

Other manuals for Shure SLX-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shure SLX-D and is the answer not in the manual?

Shure SLX-D Specifications

General IconGeneral
Audio Frequency Response20 Hz to 20 kHz
Encryption256-bit AES
Battery LifeUp to 8 hours
System TypeDigital Wireless
Transmitter TypeHandheld, Bodypack
Total Harmonic Distortion<0.02%
Latency3.2 ms
Operating RangeUp to 100 meters (328 feet)
Dynamic Range> 120 dB
Number of ChannelsUp to 32 per band
ModulationDigital
RF Sensitivity-97 dBm for 12 dB SINAD