DANGER
Ris
k of ignition
Failure to observe this information could result in a risk of ignition.
The sender, receiver, and cables delivered with the C4000 Advanced safety light
curtain are not explosion-proof. The person purchasing, assembling, and using the
safety light curtain is responsible for fitting the cables in suitable explosion-proof
conduits and/or cable glands to ensure the integrity of the system.
The type label on each individual explosion-proof enclosure contains information
on the device's hazardous area class and group. Every device that penetrates
the explosion-proof enclosure must be suitable for the environment in which the
explosion-proof enclosure is installed with regard to its hazardous area class and
group or zone.
DANGER
Risk of ignition
Failure to observe this information could result in a risk of ignition.
If the device is used in an environment classified as tbIIIC, tcIIIB or tcIIIC, the
cover must not be removed, not even temporarily (e.g. for maintenance purposes).
DANGER
Ris
k of ignition
Failure to observe this information could result in a risk of ignition.
Only if the device is used outside North America:
A cable gland must be mounted.
The cable gland must be certified for d and tb environments.
DANGER
Ris
k of ignition
Failure to observe this information could result in a risk of ignition.
Only if the device is used in North America:
Any conduit openings that are not in use must be sealed. Sealing fittings must turn
at least five (5) full revolutions and be at least 3.175 mm thick (1/8 of an inch).
Conduit sealing fittings must be applied in each installed conduit run (located a
maximum of 457 mm (18 inches) away from the explosion-proof enclosure) in
order to comply with the provisions of the most recent version of the National Elec‐
trical Code, Article 501.15 and/or 502.15, and all other applicable regulations.
2.2 General safety notes
DANGER
H
azard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
Please read this document carefully and make sure that you understand the
content fully before working with the device.
Follow all safety notes in this document.
2 S
AFETY INFORMATION
6
O P E R A T I N G I N S T R U C T I O N S | C4000 Advanced Ex 8017027/1DVD/2023-04-28 | SICK
Subject to change without notice

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Advanced Ex and is the answer not in the manual?

SICK C4000 Advanced Ex Specifications

General IconGeneral
Enclosure ratingIP65, IP67
Wavelength950 nm
Operating Voltage24 V DC
TypeSafety Light Curtain
Resolution14 mm, 30 mm
Scanning range0 m ... 7 m
Supply voltage24 V DC
Ambient operating temperature-10 °C ... +55 °C (depending on the type)
Light SourceLED
Storage Temperature-25 °C ... +70 °C

Related product manuals