EasyManua.ls Logo

SICK i200 Lock - 8 Technical Data

SICK i200 Lock
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Technical data
8.1 Technical data
Table 4: Features
Features
Variant with cable entry
Housing material Fiberglass-reinforced polyester
Enclosure rating (IEC 60529) IP 65
Mechanical service life 1 × 10
6
B
10d
(EN IS
O 13849) 2 × 10
6
Switching operation with small load
Type Type 2 (EN ISO 14119)
Coding level of the actuator Low coding level (EN ISO 14119)
Ambient operating temperature –20 °C … +60 °C
Connection type 3 × M20
Max. actuation speed 9.6 m × min
–1
Max. actuation frequency 3,600 × h
–1
Pollution degree
(e
xternal, according to EN 60947)
3 × (industry)
Max. force against which unlocking is possible 50 N
Max. retaining force, unlocked 30 N
Locking force F
ma
x
Mounting with plastic locating pins
Mount
ing with metal bolts
1,950 N
2,600 N
Locking force F
Zh
ac
cording to (EN ISO 14119)
(F
Zh
= F
max
/1.3)
Mounting with plastic locating pins
Mount
ing with metal bolts
1,500 N
2,000 N
Minimum door radii see table 7
Table 5: Electrical data
Electrical data
Thermal current l
t
h
10 A
Switching principle Slow action switching element
Wire cross-section, (rigid/flexible) 0.34 mm
2
... 1.5 mm
2
Rated insulation voltage U
i
250 V
Rated impulse withstand voltage U
im
p
2.5 kV
Utilization category (IEC 60947-5-1) AC-15: 230 V, 3 A; DC-13: 24 V, 3 A
Min. switching voltage
1)
5 V
Min. switching current at 24 V DC 5 mA
Short-circuit protection (control fuse) (IEC
60269)
6 A gG
Solenoid supply voltage (+10% … –15%) AC/DC 24 V
Max. solenoid power 7 W
ED switch-on time 100%
1)
At 10 mA.
8 TECHNICAL DATA
20
O P E R A T I N G I N S T R U C T I O N S | i200 Lock 8020558//2017-02-14 | SICK
Subject to change without notice

Related product manuals