8 Technical data
8.1 Technical data
Table 4: Features
Features
Variant with cable entry
Housing material Fiberglass-reinforced polyester
Enclosure rating (IEC 60529) IP 65
Mechanical service life 1 × 10
6
B
10d
(EN IS
O 13849) 2 × 10
6
Switching operation with small load
Type Type 2 (EN ISO 14119)
Coding level of the actuator Low coding level (EN ISO 14119)
Ambient operating temperature –20 °C … +60 °C
Connection type 3 × M20
Max. actuation speed 9.6 m × min
–1
Max. actuation frequency 3,600 × h
–1
Pollution degree
(e
xternal, according to EN 60947)
3 × (industry)
Max. force against which unlocking is possible 50 N
Max. retaining force, unlocked 30 N
Locking force F
ma
x
Mounting with plastic locating pins
Mount
ing with metal bolts
1,950 N
2,600 N
Locking force F
Zh
ac
cording to (EN ISO 14119)
(F
Zh
= F
max
/1.3)
Mounting with plastic locating pins
Mount
ing with metal bolts
1,500 N
2,000 N
Minimum door radii see table 7
Table 5: Electrical data
Electrical data
Thermal current l
t
h
10 A
Switching principle Slow action switching element
Wire cross-section, (rigid/flexible) 0.34 mm
2
... 1.5 mm
2
Rated insulation voltage U
i
250 V
Rated impulse withstand voltage U
im
p
2.5 kV
Utilization category (IEC 60947-5-1) AC-15: 230 V, 3 A; DC-13: 24 V, 3 A
Min. switching voltage
1)
5 V
Min. switching current at 24 V DC 5 mA
Short-circuit protection (control fuse) (IEC
60269)
6 A gG
Solenoid supply voltage (+10% … –15%) AC/DC 24 V
Max. solenoid power 7 W
ED switch-on time 100%
1)
At 10 mA.
8 TECHNICAL DATA
20
O P E R A T I N G I N S T R U C T I O N S | i200 Lock 8020558//2017-02-14 | SICK
Subject to change without notice