CommentBinaryRangeAttributeValue tagContainer tag
Name attribute required if
more than one Blob tool exists.
any stringnameBLOB
The name refers to the Blob
tool's name in the tool tab
Index of found blob according
to current blob sorting order.
Index 0 is the first blob
[0, 15]index
Blob center of gravity (x posi-
tion). “pixels” or “mm” depend-
ing on attribute “coordUnit”
REALcoordUnitX
Blob center of gravity (y posi-
tion). “pixels” or “mm” depend-
ing on attribute “coordUnit”
REALcoordUnitY
Number of found blobs.USINTFOUND_
BLOBS
d
The lower threshold of the Blob
tool's intensity after applying
ambient light compensation.
USINTLIVE_
THRESHOLD_
LOW
d
The upper threshold of the
Blob tool's intensity after apply-
USINTLIVE_
THRESHOLD_
ing ambient light compensa-
tion.
HIGH
d
In degrees or radians depend-
ing on attribute “unit” or con-
REAL[0, 180]unitANGLE
figured value in the Ethernet
Result output dialog.
Blob area (in pixels). In “pixels”
or “mm
2
” depending on attrib-
UDINTAREA
ute “coordUnit” or configured
value in the Ethernet Result out-
put dialog.
0 = blob fully within ROI, 1 =
blob touches ROI border
USINT{0, 1}EDGE_FLAG
Structure calculation value
(number of edge pixels inside
the found blob)
UDINTEDGE_PIXELS
0=not found, 1=foundUSINT{0, 1}DECISION
Name attribute required if
more than one Edge tool exist
any stringnameEDGE_LOCAT-
OR
X position of the reference
point. In “pixels” or “mm” de-
REALcoordUnitX
pending on attribute “co-
ordUnit” or configured value in
the Ethernet Result output dialog.
Y position of the reference
point. In “pixels” or “mm” de-
REALcoordUnitY
pending on attribute “co-
ordUnit” or configured value in
the Ethernet Result output dialog.
8015726/ZPP7/2018-
09
©SICK AG • Identification & Measuring • www.sick.com • All rights reserved
Subject to change without notice
44
Reference Manual
Result output formatting
Appendix
Inspector PIM