8016441/2013-11-22•©SICKAG•Subjecttochangewithoutnotice 17
Product description
Status indicator
Receive indicator
status (green LED)
Control element
status (display)
Description
Permanentlyon Permanentlyon Connectionavailable;thereceiveris
abletoreceiveastrongopticalsignal.
Permanentlyon Flashingslowly Thereisawarningpending,see
Page41,Chapter10.1.
Permanentlyon Flashingrapidly Thereisanerrorpending,see
Page41,Chapter10.2.
Flashingslowly Flashingslowly Warning:Thereceiverisonlyableto
receiveaweakopticalsignal.
Flashingrapidly Flashingrapidly Error:Thereceiverisnotabletoreceive
anopticalsignal.
Table 3: Status indicator
Control element
3
2
EscSet
RUN
1
Fig. 4: Control element
1 Operating mode indicator: RUN/MEN/SET
2 Receive level indicator with max. 6 bars
3 4 operating buttons
NOTE
If a value or a piece of information in menu mode
consists of more than six characters, the characters are
automatically shown successively in the display.
Symbols TheISD400Prohastwodistinctmodes:operatingmodeandmenumode.
Symbol Description
RUN TheRUNsymbolisdisplayedinoperatingmode:
•RUNislit:Deviceisreadyforoperation,Ethernetlinkis
active,datatransmissionisnotactive
•RUNisashing:Deviceisoperatinganddatatransmis-
sionisactive
•RUNisoff:Deviceisnotreadyforoperation(afaulthas
occurredornoEthernetcableisconnected)
MEN TheMENsymbolisdisplayedinmenumode.Thissymbol
isalsodisplayedwhenthereisanerrorandnodatacan
betransmitted.
SET TheSETsymbolisdisplayedifthelaserforalignmentis
switchedoffbypressingthekeycombination(pressand
holddown and atthesametime).
Table 4: Symbols for operating mode and menu mode