Mounting
22 ©SICKAG•Subjecttochangewithoutnotice•8016441/2013-11-22
5.3 Arranging multiple optical devices
Insomeapplications,multipleopticaldevicesmustbeoperatedsideby
side.Inthesecases,minimummountingdistancesmustbeobserved.
Mounting multiple ISD400 Pro
a
a > d x 0.013
d
Fig. 5: Arranging multiple ISD400 Pro
1 ISD400-7xx1, red
2 ISD400-7xx2, infrared
a Minimum distance
Formula a>dx0.013
Example • Measuringrange:0.2…150m
• d(measuringdistance):100m
Calculation
a>100mx0.013
Minimum distance result
a>1.3m