Technical data
44 ©SICKAG•Subjecttochangewithoutnotice•8016441/2013-11-22
11.2 Performance data
Lightsender • Redlaser(ISD400-7xx1):660nm
• Infraredlaser(ISD400-7xx2):785nm
Lightspotsize(distance) 1.75m(at100m);diameter=0.0175mxd(m)
Transmissionrange 0.2to150m
Apertureangle • Sender:1°
• Receiver:1.5°
Ambientlight <10klux
Table 17: Performance data
11.3 Power supply
SupplyvoltageU
V
1)
18VDCto30VDC
Circuitprotection U
V
connections,reversepolarityprotected
Powerconsumption(withoutload) • 3W(withoutheating)
• 23W(withheating)
1) Limitvalues,reversepolarityprotected
Table 18: Power supply
11.4 Interfaces
Datainterface FastEthernet
Datatransmissionrate 100Mbit/s
Signaldelay ≤1,5µs
Multifunctionaloutput
1)
Hi:U
v
–3V,Lo:<2V
MaximumoutputcurrentI
A
100mA
Multifunctionalinput Hi:>8V,Lo:<5V
1) Short-circuitandoverloadprotected
Table 19: Interfaces