EasyManua.ls Logo

SICK ISD400 Pro - 5 Mounting; 5.1 Mounting Procedure; 5.2 Mounting Instructions

SICK ISD400 Pro
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8016441/2013-11-22•©SICKAG•Subjecttochangewithoutnotice 21
Mounting
5 Mounting
5.1 Mounting procedure
1. Chooseamountingsite,bearinginmindthemountinginstructions.
Seethefollowingchapter.
2. Mountthealignmentbracketanddatatransmissionsystem.
SeePage24,Chapter5.4.
3. Maketheelectricalconnection.
SeePage26,Chapter6.
4. Alignthedevicesofthedatatransmissionsystemwithoneanother.
SeePage31,Chapter7.1.
5.2 Mounting instructions
Toensuretrouble-freeoperation,thefollowingmountinginstructions
shouldbeobserved:
• Complywithtechnicaldatasuchasthemeasuringrange.
SeePage44,Chapter11.2.
• Atlowambienttemperatures–e.g.indeep-freezewarehouses–the
datatransmissionsystemshouldhaveintegratedheating.
• Protectthedatatransmissionsystemfromdirectsunlight.
• Topreventcondensationwater,avoidexposingthedatatransmission
systemtorapidchangesintemperature.
• Makesurethesystemisasufcientdistancefromotheropticalmeasu-
ringdevicesanddatatransmissionsystems.SeePage22,Chap-
ter5.3.