8016441/2013-11-22•©SICKAG•Subjecttochangewithoutnotice 23
Mounting
Mounting the ISD400 Pro and other
optical devices
a
a > d x 0.0083
d
Fig. 6: Arranging the ISD400 Pro and a DL100 Hi distance-measuring device
1 DL100 Hi distance-measuring device
2 Reector
3 ISD400-7xx1, red
4 ISD400-7xx2, infrared
a Minimum distance
Formula a>dx0.0083
Example • Measuringrange:0.2…150m
• d(measuringdistance):100m
Calculation
a>100mx0.0083
Minimum distance result
a>0.83m