LMS4x2x
Figure 2: LMS4x2x – Warning signs on the device
1
Avoid exposure – Laser radiation is emitted from this aperture.
Laser output aperture corresponds to the front screen at the height of the position shown.
2
Caution – Laser radiation when opened. Do not stare into beam.
3
Laser radiation – Do not stare into beam. Class 2 laser product
Average radiation output: 13.5 mW
Maximum radiation output: 27 mW
Wavelength: 660 nm
IEC 60825-1:2014
Complies with 21 CFR 1040.10 and 1040.11 except for tolerances according to Laser
Notice No. 50 of June 24, 2007.
4
Warning symbol: Laser radiation
5
Do not remove – Hazardous laser radiation and risk of personal injury if the laser protec‐
tion hood is removed. Limit values of laser class 2 are exceeded.
Notes on the warning signs
•
Before commissioning, the English warning label “LASER RADIATION – DO NOT
STARE INTO BEAM” is to be replaced with a warning label in a language that the
operators of the system understand. Laser warning labels in German and French
are included in the scope of delivery.
•
If the devices are installed in a system/casing so that the warning labels are cov‐
ered, other warning labels (not included with delivery) must be attached to the
system/casing next to the laser output aperture.
SAFETY INFORMATION 2
8023198/16S6/2020-01-24 | SICK O P E R A T I N G I N S T R U C T I O N S | LMS4000
11
Subject to change without notice