Operating Instructions | SICK 65
Operating Instructions PAC50
8017612/ZAB1/2017-02-14 | PAC50
Subject to change without notice
6 Electrical connection
6 Electrical connection
The electrical connection is established using a round connector M12 x 1. Table 3, Figure 13, Table 4, and
Figure 14 display the pin assignments for the various device versions/existing output signals.
CAUTION
Please observe the information regarding the electrical properties of the pressure switch in
Section 9 (Technical data).
Output signals Type designation Electrical connection PIN assignment
2 x digital PAC50-xxA M12 x 1, 4-pin L
+
= 1, M = 3, Q
1
= 4, Q
2
= 2
1 x digital + analog PAC50-xxB M12 x 1, 4-pin L
+
= 1, M = 3, Q
1
= 4, Q
A
= 2
1 x IO-Link/digital + digital PAC50-xxD M12 x 1, 4-pin L
+
= 1, M = 3, C/Q
1
= 4, Q
2
= 2
Table 3: Pin assignment according to output signal, 4-pin
Figure 13: Pin assignment for M12 x 1, 4-pin
Output signals Type designation Electrical connection PIN assignment
2 x digital + analog PAC50-xxC M12 x 1, 5-pin L
+
= 1, M = 3, Q
1
= 4, Q
2
= 2, Q
A
= 5
1 x IO-Link/digital + digital
+ analog
PAC50-xxF M12 x 1, 5-pin L
+
= 1, M = 3, C/Q
1
= 4, Q
2
= 2, Q
A
= 5
Table 4: Pin assignment according to output signal, 5-pin