66 Operating Instructions | SICK
Operating Instructions PAC50
8017612/ZAB1/2017-02-14 | PAC50
Subject to change without notice
7 Operation and parameter settings
Figure 14: Pin assignment for M12 x 1, 5-pin
7 Operation and parameter settings
7.1 Initialization
Once the power supply has been connected, all segments on the display light up for 2 seconds in the primary
color, then 2 seconds in the warning color to check all segments are functioning correctly. The following
indications are then displayed for 2 seconds:
Display area A: "SICK"
Display area B: "PAC50"
Display areas C2 and E2: "Firmware revision"
The device then enters display mode.
7.2 In operation: Display mode
The measuring and switching functions are in operation.
The device has an energy-saving mode which switches o the display ("DISC" function). In energy-saving
mode (DISC: OFF), the display is briey reactivated (10 seconds) when one of the pushbuttons is pressed.
7.3 Info mode
Pressing the pushbutton for a longer period (> 3 s) displays the following parameters consecutively for 3
seconds each (see "Parameter info" in Section 2). The device returns to display mode subsequently: