Configuration
6.2.1 Setting the PROFIsafe address on the S3000 PROFINET IO/IOOF
In order for you to operate the S3000 PROFINET IO/IO8OF as a PROFIsafe user, this must
have a PROFIsafe address. The PROFIsafe address must correspond to the appropriate
s
etting in the FPLC network engineering tool.
For this purpose, in the network engineering tool in the PROFIBUS configuration for the bus
node, read the value of the parameter F_Dest_Add and use the value read as the
PROFIsafe address in the configuration for the S3000 with the aid of the CDS.
CDS, device symbol S3000 PROFINET IO, context menu Configuration draft, Edit, file
card General, option PROFIsafe address(F_Dest_Add).
Fig.
12
:
Corresponding
parameter in the CDS