EasyManua.ls Logo

SICK SIM2000 - Ambient Data

SICK SIM2000
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Feature Parameter
Output current
SENSOR S1-S6, I/O ≤ 100 mA, on digital output pins
SENSOR S1-S4 ≤ 1 A, on power supply pins
SENSOR S5-S6 ≤ 2.5 A, on power supply pins, switching times when using the
“Connector.Power.Gate” API:
Rise time/fall time/delay < 10 μs, max. frequency: 10 kHz
CAN ≤ 3.2 A, on power supply pins
SERIAL ≤ 1 A, on power supply pins
INC ≤ 0.5 A, on power supply pins
I/O ≤ 500 mA, on power supply pins
Housing material Aluminum die cast
Housing color Light blue (RAL 5012)
Protection class III
Weight 1995 g
Dimensions (W x D x H) 176 x 83 x 196 mm
11.4 Ambient data
Feature Parameter
Electromagnetic compati‐
bility
IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019
IEC 61000-6-3:2020
Vibration resistance IEC 60068-2-6:2007
Shock resistance IEC 60068-2-27:2008
Electrical safety IEC 61010-1:2010 + Cor.: 2011
IEC 61010-2-201:2017
Enclosure rating IP65 in accordance with EN 60529-2000-09 (requires blind plugs
to be inserted into unused connections)
Ambient conditions
Operation site
Height position
Contamination rating
Use inside buildings
max. 2,000 m
1
Ambient operating temper‐
ature
0 °C ... +50 °C, when the described mounting requirements are
taken into account, see "Mounting the device", page 16
Storage temperature -20 °C ... +70 °C
Permissible relative humid‐
ity
90%, non-condensing
TECHNICAL DATA 11
8023297//2021-06-22 | SICK O P E R A T I N G I N S T R U C T I O N S | SIM2000
41
Subject to change without notice