EasyManua.ls Logo

SICK SIM800

SICK SIM800
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Feature Parameter
USB
Quantity 1
Function USB 2.0 (Micro-B), reserved
Rotary encoding switch
Quantity 1
Function Reserved
11.3 Mechanics and electronics
Feature Parameter
Electrical connection POWER: 1 x M12, 5-pin male connector, A-coded
SERIAL, I/O: 1 x 15-pin D-Sub HD female connector, with seal
INPUT: 1 x M12, 5-pin female connector, A-coded
ETHERNET: 2 x M12, 4-pin female connector, D-coded
USB: Micro-B (under servicing panel)
Supply voltage 10 ... 30VDC, SELV in accordance with EN61010, also applies to
digital inputs
Operating current Must be limited by external power supply unit to max. 12A
Power consumption 5W max., without connected sensors
Power output Max. 100W total (all connections)
Housingmaterial Aluminum
Housing color Uncoated cast aluminum, anthracite labeling film
Protection class III
Weight 360g
Dimensions (W x D x H) 207mm x 49.5mm x 40.7mm (without cables connected)
11.4 Ambient data
Feature Parameter
Electromagnetic compati‐
bility (EMC)
Immunity to interference as per:
IEC 61000-6-2:2016/IEC61000-6-2:2005
Radiated emission as per: IEC 61000-6-3:2006+AMD 1:2010
Vibration resistance IEC 60068-2-6:2007-12
Shock resistance IEC 60068-2-27:2008-02
Electrical safety IEC 61010-1:2010 + Cor.: 2011
IEC 61010-2-201:2017
Enclosure rating IP65 as per IEC 60529 AMD 1:1999-11 (blind plugs must be
inserted into unused connections)
Altitude max. 2000m
Ambient operating temper‐
ature
–35°C ... +50°C
Storage temperature –35°C ... +70°C
Permissible relative humid‐
ity
90%, non-condensing
TECHNICAL DATA 11
8028935//2023-09-26 | SICK O P E R A T I N G I N S T R U C T I O N S | SIM800
25
Subject to change without notice