Pin Signal Function
1 DC 24 Vout Supply voltage OUT
2 nc
3 GND Supply voltage ground
4 Digital In 3 Digital input 3
5 nc
Max. 1A output for supply voltage connection
Can be wired, e.g., to PNP output of a trigger sensor
High input logic level: 6V ... 32V (0.7mA ... 5mA)
Max low input logic level: 2V (≤0.3mA)
ETHERNET 1 and ETHERNET 2 connection
1
43
2
Figure 6: M12 female connector, 4-pin, D-coded
Pin Signal Function
1 TD+ Sender+
2 RD+ Receiver+
3 TD– Sender
4 RD– Receiver
Transmission rate: max. 100Mbit/s
6.5 Connecting peripheral devices
The device can be connected to a wide range of sensors.
The required pin assignments can be found in the data sheets for the peripherals to be
connected as well as in the relevant connection descriptions, see "Pin allocation of the
connections".
1. Connect the cables to peripheral devices.
2. Route the cables to the device using installation materials (cable channels, cable
ties, etc.). When doing so, pay attention to cable strain relief.
3. Connect cables to the relevant device connections and screw together tightly.
4. Seal unused connections with dummy plugs.
6.6 Connecting voltage supply
For a list of cables suitable for use with the device, see the document “SIMxxxx_Cable-
Overview” available from supportportal.sick.com.
Customer assembly of the cables is only necessary in special cases. Ensure a sufficient
length of cable is provided, e.g., for strain-relief clamps.
6 ELECTRICAL INSTALLATION
18
O P E R A T I N G I N S T R U C T I O N S | SIM800 8028935//2023-09-26 | SICK
Subject to change without notice