11.2 Mechanics and electronics
Type Value
Electrical connection 1 x M12, 17-pin male connector (serial, I/Os, voltage supply)
1 x M12, 4-pin female connector (Ethernet)
Supply voltage DC 12 V ... 24 V, ± 20%
Voltage source as per ES1 and PS2 or lower (EN62368-1), or as
per SELV (EN60950-1)
Power consumption Typ. 4 W
Enclosure rating IP65
Weight 170 g
Housing material Aluminum die cast
Window material PMMA
11.3 Performance
Type Value
Image sensor resolution see "Type code", page 13
Scan/frame rate 50 Hz
11.4 Interfaces
Type Value
Serial
1
RS-232, RS-422
Data transmission rate: 300 Baud ... 115.2 kBaud
Ethernet TCP/IP
Function: FTP
1
, HTTP
Data transmission rate: 10/100 MBit/s
CAN
1
Function: SICK CAN sensor network (master/slave)
EtherNet/IP Data transmission rate: 10/100 MBit/s
EtherCAT®
1
Type of fieldbus integration: Optional over external fieldbus mod‐
ule CDF600
PROFINET Function: PROFINET Single Port, PROFINET Dual Port (optional via
external connection module CDF600-2)
Data transmission rate: 10/100 MBit/s
PROFIBUS DP
1
Type of fieldbus integration: Optional over external fieldbus mod‐
ule CDF600-2
Operator interfaces Web server
Configuration software Web GUI (SensorApp configuration), SICK AppStudio (program‐
ming)
Data storage and retrieval Image and data logging via microSD memory card
Image and data logging via external FTP
1
Output current ≤ 100 mA
Maximum encoder fre‐
quency
300 Hz
Operating elements 2 buttons
1
Optical indicators 16 LEDs (5 x status display, 10 x LED bar graph, 1 green/red feed‐
back spot)
11 TECHNICAL DATA
50
O P E R A T I N G I N S T R U C T I O N S | InspectorP621 8024439//2019-06 | SICK
Subject to change without notice