O P E R A T I N G I N S T R U C T I O N S
MCS200HW
Multicomponent Analysis System

Table of Contents

Other manuals for SICK MCS200HW

Questions and Answers

  • R
    rleeJul 31, 2025
    What to do if the temperature is too high in SICK Analytical Instruments?
    • C
      Casey PriceJul 31, 2025
      If the temperature is too high in your SICK Analytical Instruments, there are several things you can check. First, check the plug-in connectors. Also, if the cabinet temperature is 55°C or higher, check the cabinet fan and replace the filter pad. If the cabinet temperature is less than 55°C, check the fan of the electronics unit and clean or replace the filter pad. If the enclosure temperature is 55°C or higher, check the cabinet fan and replace the filter pad. If the enclosure temperature is less than 55°C, contact SICK Service. Also, refer to the device documentation to clarify which subassembly is affected. If T is ? 360.7 °C: Check plug-in connectors. When ok: Call SICK Service. If T < 360.7 °C: Call SICK Service. If T ? 151.2 °C: Check plug-in connectors. When ok: Call SICK Service.

Summary

Safety information

Basic safety information

Provides fundamental safety advice, document retention, correct use, and local conditions for safe operation.

Warning information on device

Details warning symbols found on the device and their meanings, including electrical and hot surface hazards.

Requirements on the personnels qualification

Outlines the necessary qualifications for personnel performing installation, commissioning, operation, and maintenance.

Product description

Layout and function

Provides an overview of the system components and their functions, including sampling, analysis, and control.

Mounting

Overview of mechanical and electrical installation

Provides an overview of the installation process and important notices regarding assembly order.

Installation sequence

Outlines the step-by-step procedure for installing the analyzer cabinet and sample gas line.

Connecting the span gases

Explains how to connect span gases to the span gas unit, including prerequisites and procedures.

Electrical installation

Disconnecting device

Instructs on installing power isolating switches or circuit breakers for voltage supply disconnection.

Connecting the power supply

Shows the location of the power supply and discusses options like UPS integration.

Commissioning

Prerequisites for switching on

Lists checks required before switching on the device, such as instrument air and pressure settings.

Switching on

Provides a step-by-step procedure for switching on the device, including expected displays and status indicators.

Operation

Maintenance

Troubleshooting

Safety

Reiterates safety requirements for maintenance personnel working on electrical systems and gas handling.

Error messages and possible causes

Introduces the section on error messages, their classification, and how to check the logbook for troubleshooting.

System Error Codes

Lists system error codes, their descriptions, and possible clearance steps for diagnosing issues.

SICK MCS200HW Specifications

General IconGeneral
Protection ClassIP65
Measured componentsCO, CO2, NO, NO2, SO2
CertificationsMCERTS
Typical applicationsEmissions monitoring
Gas pathsSingle or multiple gas paths
Response Time< 60 seconds (T90)
Output4-20 mA
Power Supply50/60 Hz
Accuracy±2% of full scale