IO-Link IO-Link is a non-proprietary internationally standardized
communication technology, which makes it possible to
communicate with sensors and actuators in industrial
environments (IEC 61131-9). IO-Link devices communicate with
higher-level control systems via an IO-Link master. The IO-Link
devices are connected to these via a point-to-point connection.
IO-Link enables communication between controllers, sensors and
actuators and allows the parameterization and reading-out of
devices to be centrally managed.
Measuring range The measuring range can be anywhere inside the detection range.
The measuring range must always be completely inside the
detection range.
MultiMode The MultiMode function is used with photoelectric sensors to select
between various operating modes: e.g., Background Suppression,
Foreground Suppression, Two-Point Teach-In, Two Independent
Switching Points or Window Mode. The operating modes can be set
using the Teach-Turn adjustment (BluePilot) and IO-Link.
The MultiMode function is used with photoelectric sensors to select
between various modes and functions: e.g., Background
Suppression, Foreground Suppression, Single Value Teach-in, Two
Value Teach-in, Manual Teach-in, Speed, Standard and Precision
Modes.
The various modes/functions can be set via the touch display or
IO-Link.
Response time The response time specifies the maximum amount of time that
elapses from when an event triggers the sensor to when a signal
is present at the output.
SOPAS ET SICK Engineering Tool for configuring IO-Link devices
Software with a graphical user interface and convenient
visualization for configuring and parameterizing IO-Link devices.
Corresponding visualization files (SDD = SOPAS Device Description)
are available for all devices so that you can operate the IO-Link
devices using SOPASET.
You can download SOPAS ET and the device-specific SDDs directly
and free of charge from the SICK homepage: www.sick.com.
Switching frequency The switching frequency expresses the number of switching
operations performed by a sensor over a defined interval of time.
13 부록
13.1 적합성 인증서
www.sick.com에서 적합성 선언서, 인증서, 제품의 최신 작동 지침서를 확인할
습니다. 이를 위해 검색 필드에 제품의 품목 번호를 입력하십시오(품목 번호: “P/N”
또는 “Ident. no.” 필드에서 명판 기재 내용 참조).
13.2 라이선스
SICK 특히 GNU General Public Licence(GPL 버전 2, GPL 버전 3), GNU Lesser
General Public Licence(LGPL), MIT 라이선스, zLib 라이선스 BSD 라이선스에서
생된 라이선스 등의 무료 라이선스 저작권자가 사용을 허가한 오픈 소스 소프트웨어
사용합니다.
소프트웨어 프로그램은 일반 공중 사용을 위해 마련된 것이지만, 어떤 보증도
제공하지 않습니다. 이러한 보증 배제 원칙은 프로그램이 특정한 목적에 적합하다거
판매용으로 사용될 있다는 묵시적 확약에도 확대 적용됩니다.
작동 지침서
204
| WTM10L 9382969/2024-02-23 | SICK
예고 없이 변경 가능
ko

Table of Contents

Related product manuals