Parameter List 09.02
5-26 Siemens AG 6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit Operating Instructions
PNU
*
: Conf.
Par.
OP1S parameter name
Description
Value range
[phys. unit]
Selection text
Display
Indices
Factory-
setting
See
Modify
(access /
status)
P624
*
Trg BitWarTmpInv
Destination of the status bit 'Warning unit overtemperature'
(status word 2, bit 24
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=270Hex; Type=L2; Scaling: 1Hex
=
1
0 to 4212 2
0
3/ BR
3/ BR
P631
*
Trg Bit Charging
Destination of the status bit 'Charging active' (status word 2, bit 31)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=277Hex; Type=L2; Scaling: 1Hex
=
1
0 to 4212 2
0
3/ BR
3/ BR
https://www.aotewell.com
AoteWell Automation Sales Team
Sales@aotewell.com
AoteWell LTD
Buy Siemens PLC HMI Drives at AoteWell.com
https://www.aotewell.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 6SE7032-2EE85-1AA0 and is the answer not in the manual?

Siemens 6SE7032-2EE85-1AA0 Specifications

General IconGeneral
BrandSiemens
Model6SE7032-2EE85-1AA0
CategoryDC Drives
LanguageEnglish

Related product manuals