09.02 Parameter List
Siemens AG 6SE7087-6AK85-1AA0
5-35
Rectifier/Regenerating Unit Operating Instructions
PNU
*
: Conf.
Par.
OP1S parameter name
Description
Value range
[phys. unit]
Selection text
Display
Indices
Factory-
setting
See
Modify
(access /
status)
r730 SCB Diagnostics
SCB diagnostics
All values in HEX display
If a quantity is represented, overflow takes place at FF Hex.
The meaning of several Indices depends of the selected SCB protocol
(P682).
i001: flTC Number of error-free telegrams
i002: Terr Number of error telegrams
i003: Ferr Number of byte frame-errors
i004: Orun Number of overrun errors
i005: Prty Parity error
i006: STX STX error
i007: ETX ETX error
i008: BCC Block check error
i009: L/KL USS/Peer to Peer: incorrect telegram length
SCI modules: required maximum number of terminals
according to process data wiring (P554 to P631).
i010: T/An USS: Timeout
SCI Modules: required analog inputs / outputs
according to process data wiring of the setpoint
channel and actual value output via SCI (P664) .
i011: BCd0 PCB code word 0
i012: BCd1 PCB code word 1
i013: Warn SCB-DPR- warning word
i014: Sl1? Information, if slave 1 needed and if yes, which type.
0: no slave needed
1: SCI1
2: SCI2
i015: Sl2? Information, if slave 2 needed and if yes, which type.
0: no slave needed
1: SCI1
2: SCI2
i016: IniF: with 'SCI modules': initialization fault
PNU=2DAHex; Type=L2; Scaling: 1Hex
=
1
16 3/ HBR
r731 CB/TB Diagnostics
For detailed information see manuals of the used communication boards
(CB) or technology boards (TB).
PNU=2DBHex; Type=L2; Scaling: 1Hex
=
1
32 3/ HBR
r748 Fault Time
The instants at which faults occur (reading of the hours counter r013 at the
instant the fault occurs)
See parameter r947 for details
Trip description by: r947 Fault number
r949 Fault value
r951 List of fault texts
P952 Number of faults
PNU=2ECHex; Type=O2; Scaling: 1Hex
=
1
24 2/ BR