A30808-X3247-L14-2-7618
11
Information
Base Station System
Technical Description (TED:BSS)
BS-240/241
Redundancy:
SW Support of Core Redundancy
SW Support of BCCH Redundancy
AC/DC n+1 redundancy. (n+1) AC/DC Converters work in load sharing, but n AC/DC
are able to supply the whole BS-240/241 including Service Racks/Shelters
Abis interface:
Enhanced Full-Rate TCH
Full-Rate and Half-Rate TCH
AMR TCH
Submultiplexing4x16kbit/s onto one 64 kbit/s timeslot for handling Full-Rate TCH
on Um interface
Handling of 4x(2x8) kbit/s onto one 64 kbit/s timeslot for half-rate TCH on Um inter-
face
Drop and insert feature on 2 Mbit/s (E1) and 1.5 Mbit/s (T1) links is available on a
16 kbit/s and a 64 kbit/s basis
Star, loop and multidrop chain connections
Cross connect function
Change of PCM line configuration from star to multidrop or loop and vice versa is
possible without any interruption of service
Multiple Abis LAPD links; load sharing and LAPD fault recovery
External clock synchronisation
Over-Voltage Protection with OVPT
Abis link media:
Wire
Fiber optic
Micro-Wave
Fault procedures:
Automatic Recovery procedure of faulty objects in BTS
Online RF Loopback

Table of Contents