EasyManua.ls Logo

Siemens BS-240 - Fig. 3.6 PATRX Block Diagram

Siemens BS-240
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A30808-X3247-L14-2-7618
31
Information
Base Station System
Technical Description (TED:BSS)
BS-240/241
Fig. 3.6 PATRX Block Diagram
The functional sub-unit PATRX consists of three PCBs:
RXA: Analogue receiver board with modules RXFEM, RXFED, RXLO and LTL
TXA: Analogue transmitter board with modules MODUP, TXLO, PWRDET
PWRSTG: Power stage including heat sink
Signal Processing Unit (SIPRO)
The SIPRO-Board is a part of the Carrier Unit. It contains all digital functions of the
carrier unit namely
Signal Processing in uplink and downlink
Control of RF on PATRX
Baseband and synthesizer hopping
Channel Control
Radio Link Control
O&M parts relevant for carrier unit
Link to Core via CC link
Additionally, following analogue functions are located on SIPRO:
Analogue to digital conversion (IF)
Digital to analogue conversion (baseband)
Local clock of CU
Due to the analogue functions, SIPRO is specific for the different frequency variants.
There are two types of SIPROs (one for GSM 850, GSM 900, one for GSM 1800, GSM
1900).
Fig. 3.7 illustrates the principal data flow on SIPRO:
receives two (diversity!) IF signals from the receiver, then analogue to digital conver-
sion takes place. The next step is digital downconversion to base band and filtering.
The output of the filter is equalized. The soft decisions from the equalizer then are
deciphered. The deciphered data stream is processed by the decoder. After
decoding (including bad frame indication), the data stream is packed into TRAU
to SIPRO for
LCLK from SIPRO
GMSK modulated
TXBB
Rx input
Tx output
RXFEM
RXFED
RXLO
TXLO
LTL
PWSTG
MODUP
PWRDET
(diversity)
downconversion
to baseband
signal from SIPRO
RF Control
from SIPRO
from SIPRO

Table of Contents

Related product manuals