Load value
You can determine an initial value (load value) for each counter on the FM 450-1 The counter is
set at the initial value if a software or hardware-related signal to the module comes up.
Hardware interrupts
When comparison values are reached, for over󹪞ow, under󹪞ow and/or for zero crossing of a
counter, the FM 450-1 can trigger a Hardware interrupt.
Diagnostic interrupt
When the following events occur, the FM 450-1 can trigger a diagnostic interrupt:
External auxiliary voltage faulty
Encoder 5.2 VDC supply faulty
Module not assigned parameters or errors in parameter assignment
Watchdog timeout
RAM defective
Hardware interrupt lost
Fault in signal A, B, or N of the 5 V encoder
Pulse duration
You can determine a pulse duration for the digital outputs of the FM 450-1. The pulse duration
is used to specify how long the corresponding digital output is to be set. You can specify a value
between 0 and 500 ms for the pulse duration. This value applies to both outputs. By prescribing
a pulse duration you can adapt the FM 450-1 to existing actors.
Which signals can the FM 450-1 count?
The FM 450-1 can count signals that are generated by the following encoders:
Incremental 5-V encoders
Incremental 24-V encoders
24-V pulse encoders with direction level
24-V initiators without direction level
e.g., light barrier or BERO
Product Overview
1.2 Properties
Counter module FM 450-1
10 Equipment Manual, 03/2022, A5E03648739-AC