3.
Press the
⁠ button repeatedly until ⁠ is highlighted
on the display.
4.
Use the ⁠ or ⁠button to set the time.
a After a few seconds, the appliance starts heating
and the cooking time counts down.
5.
Once the time has elapsed, the display shows the
time as zero. The appliance stops heating up and
responds again as usual outside of Sabbath mode.
Switch off the appliance.
The appliance automatically switches off after ap-
prox.10to 20 minutes.
15  Basic settings
You can configure the basic settings for your appliance to meet your needs.
15.1 Overview of the basic settings
Here you can find an overview of the basic settings and factory settings. The basic settings depend on the features
of your appliance.
Display Basic setting Selection
⁠ ⁠ ⁠ Signal duration upon completion of a time or
timer period
⁠ = 10 seconds
⁠ = 30 seconds
1
⁠ = 2 minutes
⁠ ⁠ ⁠ Waiting time until a setting is applied ⁠ = 3 seconds
1
⁠ = 6 seconds
⁠ = 10 seconds
⁠ ⁠ ⁠ Button tone when pressing a button ⁠ = off
⁠ = on
1
⁠ ⁠ ⁠ Brightness of the display illumination ⁠ = dark
⁠ = medium
1
⁠ = bright
⁠ ⁠ ⁠ Time display ⁠ = hide the time
⁠ = display the time
1
⁠ ⁠ ⁠ Childproof lock can be adjusted
→"Childproof lock", Page20
⁠ = no
⁠ = yes
1
⁠ = yes, with locked door
⁠ ⁠ ⁠ Interior lighting during operation ⁠ = no
⁠ = yes
1
⁠ ⁠ ⁠ Cooling fan run-on time ⁠ = short
⁠ = medium
1
⁠ = long
⁠ = extra-long
⁠ ⁠ ⁠ Telescopic shelves retrofitted
2
⁠ = no
1
(for rails and 1-level pull-out)
⁠ = yes (for 2- and 3-level pull-out)
⁠ ⁠ ⁠ Sabbath mode available
→"Sabbath mode", Page20
⁠ = no
1
⁠ = yes
⁠ ⁠ ⁠ Water hardness
→"Setting the water hardness", Page22
⁠ = softened
⁠ = soft (up to 1.5mmol/l)
⁠ = medium (1.5–2.5mmol/l)
⁠ = hard (2.5–3.8mmol/l)
1
⁠ = very hard (above 3.8mmol/l)
⁠ ⁠ ⁠ Automatic rapid heating from 200°C
2
⁠ = no
⁠ = yes
1
⁠ ⁠ ⁠ Reset all values to factory settings ⁠ = no
1
⁠ = yes