Siemens Building Technologies Basic Documentation LMU54... / LMU64... CC1P7494en
HVAC Products 1 Overview 07.11.2002
Integrated DHW systems with specific algorithms for storage tank, stratification
storage tank, instantaneous and aquabooster systems
Instantaneous DHW heating systems with optional comfort function
DHW heating with charging pump / diverting valve
Diverting valve control via stepper motor control, N.O. contact with continuous phase
or changeover contact
DHW control with sensor or thermostat
Control of DHW circulating pump with QAA73...-V1.4
Integrated weather-compensated pump heating circuit
PWM-controlled heating circuit pump with specific algorithms to ensure most effective
condensation, improved overall efficiency and enhanced room comfort (optional)
Additional weather-compensated heating circuit for single-user applications via
modular clip-in add-on module AGU2.500 (pump or mixing heating circuit) with
independent minimum / maximum limitation and heating curve.
Independent time switch program in connection with the QAA73...
Automatic summer / winter changeover
Automatic 24-hour heating limit (with no RU connected)
Quick setback (with no RU connected)
Compensation variants with room thermostat / time switch (single- or dual-channel
time switch)
Compensation variants with room controls via integrated interface based on
OpenTherm (QAA73... / QAA53...)
Integrated interface on OpenTherm basis
Communication capability via the Local Process Bus (LPB) by means of clip-in
module
Consistent system architecture of RVA… controllers
Optional remote supervision
Connection via LPB clip-in module to
RVA46... zone controllers
RVA47... cascade controllers
RVA63... boiler and heating circuit controllers
RVA65... energy managers for solar, wood, etc.
RVA66... boiler and heating circuit controllers
OCI6... communication interface for remote supervision (in connection with
appropriate ACS… software)
1)
Modular and flexible concept of operating units AGU2.3...; optionally with housings for
flush panel mounting, degree of protection IPX4D (splash-proof) and LCD model with
clock function and backlit display
Chimney sweep function
Controller stop function for output adjustment
Error messages with lockout storage and fault history
Display and interrogation of all relevant process parameters via operating units,
QAA73... and PC tool
Counter for the number of startups and the number of operating hours
Maintenance functions with service message
1)
Automatic plant configuration (identification of RU, connected HMI, sensors, etc.)
1) Planned; on request
DHW
Heating circuit
System application
Operation / service